TM 10-3510-208-12
Clean parts using compressed air and a dry clean
(4) Remove the key (7).
cloth.
(6) Remove the setscrew (8) securing the
c. Inspection and Repair.
pulley (9) to the shaft.
(1) Inspect the tumbler temperature control
(6) Remove the key (10).
and temperature exhaust thermometer for damage,
(7) Remove the grease fittings (11) from the
(2) Replace all damaged parts.
pillow blocks (18) .
(8) Remove nuts (12), lockwashers (13),
the tumbler temperature control and temperature
exhaust thermometer.
flatwashers (17) securing the pillow block assembly
to bracket.
4-46. Exhaust Fan, Bracket and Jackshaft
(9) Slide the pillow blocks (18) off the blower
a Removal.
shaft (19).
(1) Remove the nuts (1, fig. 4-56) and lock-
(10) Remove nuts (20), lockwashers (21),
washers (2) securing the tumbler exhaust fan
assembly to the dryer-tumbler.
flatwashers (25) and remove the exhaust fan
(2) Remove the tumbler exhaust fan assembly
bracket (26) from the exhaust fan cover (27).
from the dryer-tumbler.
(3) Remove cotter pin (3), nut (4) and flat-
washer (5) securing the exhaust fan (6) to shaft.
4-72