TM 10-3510-209-10
2-2. LOCATION AND USE OF CONTROLS AND INDICATORS. (CONT)
Key
Control or Indicator
Function/Use
1
Temperature Gage
Indicates temperature of water coming from
water heater
2
Float Level
Controls amount of water allowed inside
cylinder
3
1 5-Amp Fuses
Protects the 240 V circuit
4
10-Amp Fuses
Protects the 240 V circuit
5
Timer Control
Controls time of operation during manual
operation
6
ENABLED POSITION Switch
Activates signal indicator light during
manual operation
7
DRAIN REUSE Switch
Not used (nonfunctional)
8
SIGNAL Indicator Light
Alerts operator that attention is required at
the washer controls
9
COLD WATER Switch
Turns cold water valve on/off
10
HOT WATER Switch
Turns hot water valve on/off
11
WATER LEVEL Switch
Selects high and low water levels
12
DRAIN Switch
Opens and closes drain valve
13
SIGNAL Cancel Switch
Cancels signal indicator light
14
CONTROL NO 2 Switch
Not used (nonfunctional)
15
TEMPERATURE NO 1 Switch
Not used (nonfunctional)
16
MOTOR Switch
Turns drive motor on/off
17
MASTER Switch
Turns controller on/off and operates chart
drive motor
18
TIMER Indicator Light
Indicates machine is on and cylinder is
advancing during automatic operation
19
Interior Light
Indicates to operator that power is on and
unit is in operation
20
Door Latch
Provides access to washer drum
21
Control Knob
Manually advances cylinder
22
Reset Button
Resets motor circuit breaker
23
Soap Chute
Allows operator to add supplies during the
washing cycle.
Change 2 2-3