TM 10-3510-209-10
2-2. LOCATION AND USE OF CONTROLS AND INDICATORS. (CONT)
Key
Control or Indicator
Function/Use
1
Fuel Pressure Gage
Indicates pressure of fuel to burner.
2
Burner-Air Intake
Controls amount of air to burner.
a.
Turned downward, increases air to burner.
b.
Turned upward, decreases air to burner.
3
Door Limit Switch
Stops tumbler rotation when dryer door is
opened.
4
Electric Timer
Controls drying time.
5
Start/Stop Buttons
Starts and stops blower motor and turns
ignition on and off.
6
Buzzers
Alerts operator that a safety shutdown has
occurred.
7
UV Scanner Indicator light
Gives visual indication that a safety shutdown
has occurred.
8
Exhaust Temperature Gage
Indicates temperature of drying air inside
tumbler.
9
Temperature Control
Controls temperature inside of tumbler.
10
Tumbler Burner Sight Glass
To observe flame inside the burner.
11
Air Shutter
Allows operator to fine-tune air fuel mixture.
12
Burner Fuel Shutoff Valve
Opens and closes fuel supply to burner.
2-5