TM 10-3510-209-24
2-25. AIR TANK ASSEMBLY
This task covers:
a. Inspection
b. Removal
c. Installation
INITIAL SETUP
Tools
General Safety Instructions
General mechanic's tool set,
SC 5180-90
WARNING
Compressed air used in this equipment can cause death or serious
Personnel Required
injury if proper safety precautions are not followed.
MOS 63J (1)
WARNING
High voltage is present on this equipment. Do not perform maintenance
with power on. Death or serious injury may result.
Equipment Condition
TM 5-6115-585-12, Generator off.
TM 10-3510-209-10, Water pump removed.
Paragraph 2-27, Pre-extraction bin removed.
INSPECTION
Inspect air tank for damaged or missing pressure gage
and loose or damaged fittings.
REMOVAL
1.
Open petcock (1) and drain air tank.
NOTE
Tagging of lines for same fitting at
installation is not needed.
Change 1 2-97