TM 10-3510-209-24
2-32. WATER HEATER ASSEMBLY (CONT)
ADJUSTMENT (Cont)
1.
For adjustment of fuel pump, refer to para 2-37.
2.
For adjustment of burner electrodes, refer to
para 2-34.
3.
Adjust operating temperature control (6). Turn
knob from 0 to 250 degrees and check pointer
calibration. Adjust position by loosening setscrew and
moving knob to correct position. Tighten setscrew.
REPAIR
NOTE
Remove and replace only those Items
necessary to make repair.
1.
Repair of water heater assembly consists of replacing defective components and making needed adjustments.
Refer to individual water heater component paragraphs.
2.
After replacing the defective components, ensure that the water heater is operating correctly by making a visual
inspection and performing an operational check. (Refer to TM 10-3510-209-10.)
NOTE
FOLLOW-ON MAINTENANCE:
Install tarp assembly (TM 10-3510-209.10).
2-112 Change 1