TM 10-3510-209-24
2-31.2 EXTRACTOR PIPING
This task covers:
a. Removal
b.
Repair
c.
Installation
INITIAL SETUP
Tools
General Safety Instructions
General Mechanics Tool Kit (App B, Item 1)
WARNING
Materials/Parts
High voltage is present on this equipment. Do not
Antiseize Compound (App C, Item 26)
perform maintenance with power on. Death or serious
injury may result.
Equipment Condition
Laundry Unit shut down (TM 10-3510-209-10)
REMOVAL
1.
Remove coupling half (1) from adapter (2).
2.
Remove four bolts (3).
3.
Remove flange (4) with attached piping (6) and gasket (5) from extractor (7).
4.
Remove flange (4) from piping (6).
5.
Remove adapter (2) from piping (6).
REPAIR
1.
Repair consists of replacing damaged or missing components of the extractor piping.
INSTALLATION
1.
Clean threads and apply antiseize compound to all male threads.
2.
Install flange (4) on piping (6).
3.
Install adapter (2) on piping (6).
4.
Install gasket (5) and flange (4) on extractor (7) with four bolts (3).
5.
Install coupling half (1).
2-110.2 Change 4