TM 10-3510-209-24
Table 3-1. Intermediate Direct Support Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
WASHER CYLINDER ROTATES BUT AUTOMATIC FUNCTIONS DO NOT OPERATE.
Step 1.
Check for blown fuse on controller assembly.
a.
If fuse is blown, replace fuse.
b.
If fuse is not blown, proceed to next step.
Step 2.
Check for inoperative transformer or relay in controller assembly. (See FIGURE 2-2.)
a.
Replace transformer or relay. (Refer to paragraph 3-11.)
b.
If problem persists, notify your supervisor.
EXTRACTOR ASSEMBLY
6.
EXTRACTOR FAILS TO START.
Step 1.
Check for improper function and/or improper adjustment of lid-closed microswitch. With power off, measure
continuity of lid-closed microswitch as lid is opened and closed.
a.
If switch does not work, replace or adjust lid-safety switch. (Refer to paragraph 3-18.)
b.
If switch works properly, proceed to next step.
Change 2 3-4.1/(3-4.2 blank)