TM 10-3510-209-24
3-26. DRYER UV SCANNER AND FLAME SAFEGUARD ASSEMBLY (CONT)
TEST (Cont)
5.
Remove three screws (3) and cover plate (4).
CAUTION
Ensure that power is off before
making continuity check. Damage to
test equipment could result.
6.
Use a multimeter and check continuity from
input terminals to output terminals on motor
contactor solenoid (5). Meter should indicate
open circuit at each set of terminals. Push up
on motor contactor solenoid. Meter should
indicate continuity at each set of terminals.
7.
Loosen screw (6) and remove cover (7) on flame
safeguard control.
WARNING
Remove
rings,
bracelets,
wristwatches, and neck chains before
working around or on the laundry
unit.
Jewelry
can
catch
on
equipment and cause injury, or may
short across an electrical circuit and
cause severe burns or electrical
shock.
WARNING
Use
extreme
caution
when
performing the following test with
power ON.
8.
Push dryer start switch and check for 120 V ac
at test points (8) and (9) with multimeter. If
voltage is not normal, test for 120 V ac input to
dryer (FIG. 2-4). If voltage is normal, go to next
step.
9.
Push dryer stop switch and remove two screws
(10) and flame safeguard control circuit card (11).
3-119