TM 10-3510-209-24
3-25. DRYER ELECTRIC CONTROL ASSEMBLY (CONT)
REMOVAL (Cont)
b.
Open dryer electrical panel cover (10) and
remove plastic wire ties as required.
c.
Tag and disconnect wires (11) from
electrical panel (12).
d.
Remove four nuts (13), washers (14),
conduit nut (15), and timer (16) from dryer.
e.
Remove conduit (17) from the base of
timer (16).
REPAIR
1.
Repair of the thermoswitch control assembly is
limited to replacement with a new assembly.
2.
Repair
of
the
dryer
timer
is
limited
to
replacement with a new item.
INSTALLATION
1.
Install thermoswitch control assembly.
a.
Install thermoswitch (9) on the dryer.
b.
Route wires (5) through conduit (7) and
install the conduit on thermoswitch (9).
c.
Install conduit connector (8) on the
electrical connector box (3).
d.
Connect wires (5) to terminals and
connectors in electrical connector box (3).
Remove tags.
e.
Install plastic wire ties (Item 11, App C) as
required.
f.
Position cover (2) on electrical connector
box (3) on dryer blower motor (4) and
secure with two screws (1).
3-116