TM 10-3510-220-24
3-11. WASHER CONTROLLER ASSEMBLY (CONT)
TEST (Cont)
6.
Inspect each component and wire for burns or breaks and replace defective items.
7.
Check continuity of timer, timer motor, reversing motor, and transformer. Replace defective
items.
8.
Inspect terminal strips for corrosion, loose screws, frayed wires, and insulation breaks.
SERVICE
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207
kPa). Use only with effective chip-guarding and personal-protective
equipment (goggles, shield, gloves, etc).
1.
Clean interior of controller with compressed air.
2.
Wipe exterior of controller with a damp cloth (Item 3, App C).
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective
goggles and gloves and use only in a well-ventilated area. Avoid
contact with skin, eyes, and clothes and dont breathe vapors. Do not
use near open flame or excessive heat. The flash point is 100- 138°F (38
- 59°C). If you become dizzy while using cleaning solvent, get fresh air
immediately and get medical aid. If contact with eyes is made, wash
your eyes with water and get medical aid immediately.
3.
Clean metal parts with drycleaning solvent (Item 10, App C).
4.
Clean electrical parts with dry compressed air and a clean, dry cloth.
3-32