TM 10-3510-220-24
3-11. WASHER CONTROLLER ASSEMBLY (CONT)
ADJUSTMENT
Adjust switch in timer (2) using multimeter set to
resistance scale. Connect multimeter to common
(4) and normally open (5) contacts. Without a card
(3) in timer (2) adjust Allen screw (6) until meter
shows open, put card (3) in timer (2) such that
uncut portion of card (3) covers the trip of the
switch being adjusted, if meter shows circuit with
card in the switch is properly adjusted, if not, turn
adjusting screw (6) until circuit is established.
Then remove card (3) and recheck. Repeat check
on other tracks as required.
REPAIR
WARNING
1.
2.
3.
High voltage is present on this equipment. Do
not perform maintenance with power on.
Death or serious injury may result.
Inspect for cracks, breaks, dents, or other
damage.
WARNING
Welding procedures specified may cause
injury if safety precautions are not followed.
Wear protective clothing and eyewear while
performing welding operations. Serious
injury could result.
Weld minor cracks or breaks, straighten
dents, and replace missing or damaged
hardware.
Replace controller box (1) if damaged
beyond repair.
NOTE
A record of wire removal is needed so that
installation hookup is exactly duplicated.
Refer to Figure 2, Appendix E for wiring
connections.
3-33