Table 2-2. Unit Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
W A S H E R A S S E M B LY
33. WASHER WILL NOT FILL AND CYLINDER WILL NOT ROTATE.
Check for failure of door safety switch (3). Perform continuity check with power off.
NOTE
Door lock cover must be removed to check switch.
a.
If door safety switch (3) is defective, replace switch.
(1)
Remove two screws (4) securing switch (3) to door lock bracket (1).
(2)
Tag and disconnect wires from switch (3).
(3)
Connect wires to new switch (3) and remove tags.
(4)
Attach switch (3) to door lock bracket (1) through insulator sheet (2)
using screws (4) remove in step 1.
(5)
Reinstall door lock cover removed to perform check.
b .
If switch is serviceable and problem persists, notify your supervisor.