TM 10--3510--221--10
0012 00--13
LAUNDRY ADVANCED SYSTEM OPERATION UNDER USUAL CONDITIONS
PREPARATION FOR MOVEMENT -- Continued
0012 00
PREPARATION FOR MOVEMENT -- Continued
G. Disconnect Fuel Supply
WARNING
Hose(s) connections must not be left uncovered when stowed. Dirt or other
contamination on connections can cause damage to heater fuel system.
1. Disconnect adapter (1) from MEP--805A generator (TM 9--6115--644--10).
2. Disconnect fuel hose (2) from adapter (1).
3. Roll fuel hose (2) back towards fuel hose (3).
4. Disconnect fuel hose (2) from fuel hose (3).
5. Install dust plug (4) and cap (5) on fuel hoses (2 and 3).
6. Disconnect fuel hose (3) at inlet port (6) and outlet port (7).
7. Install dust plugs (4) and caps (5) onto fuel hose (3), inlet port (6), and outlet port (7).
8. Roll up fuel hose (3) while draining fuel back into fuel supply.
9. Disconnect fuel hose (3) at fuel probe (8).
10. Remove fuel probe (8) from fuel supply.
8
3
3
3
2
5
4
5
5
2
6
7
4
1