TM 10--3510--221--10
0035 00--1
COALESCER FILTER CARTRIDGE REPLACEMENT
0035 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Operator
REMOVAL
WARNING
Distillate piping can reach temperatures near 200o F when the water recycle system is
operating. Always wear gloves and eye protection. Failure to follow this precaution could
result in severe burn injuries.
1. Close manual valve (1) at outlet of distillate pump (2).
2. Disengage two latches (3), then open access door (4).
3. Push in on end of fitting (5), then pull drain tube (6) out of piping (7).
4. Loosen clamp (8) then separate cover (9) from body (10).
5. Remove and discard cartridge (11) and gasket (12).
6. Rinse inside of cover (9) with water.