WATER RECYCLE SYSTEM THEORY
OF OPERATION -- Continued
0004 00
WATER CONDENSING -- Continued
When the water level is near the bottom of the standpipe, a signal from the level sensor to the control system will turn
off the distillate pump. With the distillate pump on water is pumped to the coalescer and back to the rinse 2 tank.
Prior to entering the coalescer water may pass through the subcooler for additional cooling. The subcooler is an air to
water heat exchanger that is only used when the temperature of the water returning to the rinse 2 tank is to hot to use
for the laundry process. In this circumstance the signal from temperature sensor (TE202), located at the inlet to the
rinse 2 tank, will prompt the control system to close solenoid valve (FV200) and open solenoid valve (FV201). When
the valves reposition, water is forced to circulate through the subcooler before it gets to the coalescer. As the water is
passing through the coil of the subcooler, ambient air is drawn through the cooling fins by the still condenser fan.
When the temperature of the water returning to the rinse 2 tank is acceptable, solenoid valve (FV200) is opened, and
solenoid valve (FV201) is closed, allowing the water going into the coalescer to bypass the subcooler.
THERMAL
FLUID
HAND
VALVE
(HV)
SLUDGE
WASTE
COOL
AIR
HOT AIR
STILL CONDENSER
STILL
CLEAN
OUT
DOOR
COOL
AIR
SLUDGE
WASTE
DN
200
DN
200
PT
200
M200
ZS
200
ZS
200
STEAM TO
EDUCTORS
POSITION
SWITCH
DOOR
LOCK
DOOR
LOCK
POSITION
SWITCH
STEAM
RELIEF
VALVE
DIRTY
WATER
LEVEL
SENSOR
PRESSURE
SENSOR
TEMPERATURE
SENSOR
TE
200
CLEAN
OUT
DOOR
HV
TE
201
TEMPERATURE
SENSOR
CONDENSATE
TO STANDPIPE
VACUUM
BREAKER
HV
FROM MANUAL
ANTI--FOAM
PUMP
ANTI--FOAM
SUPPLY
ANTI--
FOAM
PUMP
M202
FS
200
FLOW
SWITCH
LT
200