TM 10--3510--221--24
0027 00--1
DRUM WILL NOT BALANCE OR SHAKING EXCESSIVELY
0027 00
THIS WORK PACKAGE COVERS:
Troubleshooting Drum Will Not Balance or Shaking Excessively Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control
Multimeter (Item 2, WP 0272 00)
enclosure (WP 0010 00).
NOTE
Laundry load exceeding 200 lbs per drum will not balance properly.
1. Unlock and open drum door.
2. Check for excessive load.
Was too much laundry loaded?
YES Remove excess load. Go to step 4.
NO Go to step 3.
3. Check for laundry bags twisted into large groups.
Were laundry bags twisted together?
YES Untwist bags. Go to step 4.
NO Go to step 4.
4. Close and lock drum door.
5. Continue or start a laundry cycle (TM 10--3510--221--10).
Does laundry cycle finish without any shaking or balancing problems?
YES Return to normal operation.
NO Go to step 6.
6. Pause laundry cycle (TM 10--3510--221--10).
7. Check reading on air bag pressure regulator gauge.
Does gauge read 64 to 67 psig?
YES Go to step 10.
NO Go to step 8.