TM 10--3510--221--24
0037 00--4
TYPICAL TANK NOT FILLING -- Continued
0037 00
25. Use maintenance menu to open drum outlet valve. Verify valve is open.
Is valve open?
YES Go to step 26.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
26. Verify drum inlet valve is closed.
Is valve closed?
YES Go to step 27.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
27. Verify still inlet valve is closed.
Is valve closed?
YES Go to step 28.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
28. Check for debris in water pump strainer (TM 10--3510--221--10).
Is strainer clear of debris?
YES Go to step 29.
NO Clean and replace strainer. Return to normal operation.
29. Check for blockage in water plumping.
Is blockage found?
YES Clear blockage as required.
NO Replace water pump (WP 0144 00).
END OF WORK PACKAGE