TM 10--3510--221--24
0037 00--2
TYPICAL TANK NOT FILLING -- Continued
0037 00
6. Check power switch on water supply pump.
Is switch in ON position?
YES Go to step 7.
NO Position switch to ON. Return to normal operation.
7. Check petcock on water supply pump.
Is petcock closed?
YES Go to step 8.
NO Close petcock. Return to normal operation.
8. Check shutoff valve at garden hose connection on water plumbing.
Is valve closed?
YES Go to step 9.
NO Close valve. Return to normal operation.
9. Check petcocks on LADS water pumps.
Are petcocks closed?
YES Go to step 10.
NO Close petcocks. Return to normal operation.
10. Check caps on water supply manifolds.
Are caps installed?
YES Go to step 11.
NO Install cap(s). Return to normal operation.
11. Check LADS water plumbing for class III leaks.
Are any leaks found?
YES Repair as necessary.
NO Go to step 12.
12. Use maintenance menu to turn on water supply pump (WP 0010 00).
Does water supply pump come on?
YES Go to step 13.
NO Go to WATER SUPPLY PUMP DOES NOT TURN ON FAULT (WP 0050 00).
13. Use maintenance menu to turn off water supply pump.
14. Use maintenance menu to check water level in each tank and/or visually check tank water levels.
Are any tanks filled?
YES Go to step 15.
NO Go to step 16.