TM 10--3510--221--24
0060 00--1/2 blank
STILL PRESSURE LO
0060 00
THIS WORK PACKAGE COVERS:
Troubleshooting Still Pressure Lo Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control
enclosure (WP 0010 00).
1. Check drain valves at bottom of still.
Are drain valves closed?
YES Go to step 2.
NO Close drain valves. Return to normal operation.
2. Check vacuum breaker for signs of class III leakage.
Is vacuum breaker leaking?
YES Replace vacuum breaker (WP 0156 00).
NO Return to normal operation.
END OF WORK PACKAGE