TM 10--3510--221--24
0063 00--2
STILL NOT FILLING -- Continued
0063 00
7. Use maintenance menu to open and close still inlet valves (FV109A and B). Verify valves open and close.
Do valves open and close?
YES Go to step 8.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
8. Use maintenance menu to open and close drum outlet valves (FV107A and B). Verify valves open and
close.
Do valves open and close?
YES Go to step 9.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
9. Use maintenance menu to open and close rinse 2 tank outlet valves (FV105A and B). Verify valves open
and close.
Do valves open and close?
YES Go to step 10.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
10. Use maintenance menu to open and close drum inlet valves (FV106A and B). Verify valves open and close.
Do valves open and close?
YES Go to step 11.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
11. Use maintenance menu to open and close wash tank inlet valves (FV101A and B). Verify valves open and
close.
Do valves open and close?
YES Go to step 12.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
12. Check for debris in water pump strainer (TM 10--3510--221--10).
Is strainer clear of debris?
YES Go to step 13.
NO Clean and replace strainer. Return to normal operation.
13. Check for blockage in water plumping.
Is blockage found?
YES Clear blockage as required.
NO Return to normal operation.
END OF WORK PACKAGE