TM 10--3510--221--24
0058 00--1
STANDPIPE NOT EMPTYING
0058 00
THIS WORK PACKAGE COVERS:
Troubleshooting Standpipe Not Emptying Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control
enclosure (WP 0010 00).
1. Observe operator panel display.
Does LT201 FAILURE appear?
YES Go to TYPICAL LT FAILURE FAULT (WP 0033 00).
NO Go to step 2.
2. Observe operator panel display.
Does DISTILLATE PUMP OVERLOAD appear?
YES Go to DISTILLATE PUMP OVERLOAD FAULT (WP 0055 00).
NO Go to step 3.
CAUTION
Never run distillate pump without water in standpipe. Running pump dry may cause
permanent damage to pump internal components
3. Use maintenance menu to read water level in standpipe (WP 0010 00).
In standpipe level > 10 inches?
YES Go to step 5.
NO Go to step 4.
4. Fill standpipe through overflow hose to at least 10 inches.
5. Use maintenance menu to turn on distillated pump (WP 0010 00). Observe pump operation for 2 to 3
seconds then turn off pump.
Does pump come on?
YES Go to step 6.
NO DISTILLATE PUMP DOES NOT TURN ON FAULT (WP 0065 00).
6. Check position of manual valve at outlet of distillate pump.
Is valve open?
YES Go to step 7.
NO Open valve. Return to normal operation.