TM 10--3510--221--24
0109 00--1
OVERHEAD LIGHT DOES NOT TURN ON
0109 00
THIS WORK PACKAGE COVERS:
Troubleshooting Overhead Light Does Not Turn On Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control
Multimeter (Item 2, WP 0272 00)
enclosure (WP 0010 00).
1. Check position of SW1.
Is SW1 in ON position?
YES Go to step 2.
NO Position SW1 to ON. Return to normal operation.
2. Turn on overhead.
Does overhead light turn on?
YES Return to normal operation.
NO Go to step 3.
3. Check plug connection for light at GFI receptacle on main control enclosure.
Is light plugged in?
YES Go to step 4.
NO Plug in overhead light. Return to normal operation.
4. Check status of trip button on GFI receptacle on main control enclosure.
Is button tripped?
YES Reset button. Go to step 5.
NO Go to step 6.
5. Turn on overhead light.
Does overhead light turn on and stay on?
YES Return to normal operation.
NO Check for shorted wire connection on overhead lights.
6. Open door on main control enclosure and position SW1 to ON.
7. Check position of CB8.
Is CB8 in ON position?
YES Go to step 8.
NO Position C8 to ON. Go to step 12.