TM 10--3510--221--24
0111 00--3
LAUNDRY ADVANCED SYSTEM
PREVENTIVE MAINTENANCE CHECKS AND SERVICES -- Continued
0111 00
TABLE 1. Unit PMCS.
ITEM
NO.
INTERVAL
MAN--
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
1
Monthly
Inverter
enclosure
demister mesh
Clean demister mesh (1).
a. Loosen six 1/4--turn fasteners (2) to
allow inlet duct (3) to swing down.
b. Pull demister mesh (1) out of inlet duct
(3).
c. Rinse demister mesh (1) with water until
all dirt is removed. Let air dry
d. Inspect demister mesh (1) for obvious
damage. Replace if damage.
e. Install demister mesh (1) into inlet duct
(3).
f. Push up on inlet duct (3) until it mates
with inverter enclosure (4), then tighten six
1/4--turn fasteners (2).
Demister mesh
is damaged or
not clean
The callouts on this illustration match the callouts in the MONTHLY PMCS for item number 1.
4
1
2
3
ROTATED 90