TM 10--3510--221--24
0109 00--2
OVERHEAD LIGHT(S) DOES NOT TURN ON -- Continued
0109 00
8. Check for >100 VDC between CB8 terminal (L1) and TB1 terminal (N).
Is > 100 VDC present?
YES Go to step 9.
NO Check wire connections between CB8 and TB1. Repair as necessary.
9. Check for > 100 VDC between CB8 terminal (T1) and TB1 terminal (N).
Is > 100 VDC present?
YES Go to step 10.
NO Replace CB8 (WP 0219 00).
10. Check for > 100 VDC between (+) terminal on GFI receptacle and TB1 terminal (N).
Is > 100 VDC present?
YES Go to step 11.
NO Check wire connections between CB8 and GFI receptacle. Repair as necessary.
11. Replace and turn on new overhead light.
Does new overhead light turn on and stay on?
YES Return to normal operation.
NO Replace GFI receptacle (WP 0253 00).
12. Turn on overhead light.
Does overhead light turn on and stay on?
YES Return to normal operation.
NO Go to step 13.
13. Check wire connections between CB8 and GFI receptacle.
Are wire connections OK?
YES Replace GFI receptacle (WP 0253 00).
NO Repair as necessary.
END OF WORK PACKAGE