TM 10--3510--221--24
0006 00--2
AIR SYSTEM THEORY OF
OPERATION -- Continued
0006 00
PRODUCT AIR DISTRIBUTION -- Continued
A filter is mounted at the manifold inlet to prevent particles from plugging the orifices. An inlet orifice is provided to
isolate the individual level sensor orifices from pressure and flow surges. Eight level sensor orifices are used to
supply a steady flow of low pressure air to the pressure sensor and bubbler tube used to determine the water levels in
the wash tanks, rinse tanks, still, and stand pipe. The air provided to the drum air bags passes through a regulator
that is set to deliver air at 65 psig. The regulator is adjustable and contains a pressure gauge (PI501) that indicates
the regulated pressure. Each front air bag has a leveling valve that is mechanically connected to the drum. When the
LADS is operating on unlevel terrain the leveling valve adds or vents pressure from the air bag until the drum is level
in the side--to--side direction.
AIR
INLET
COALESCING
FILTER
DEHYDRATOR
AIR
FILTER
M500
AIR TANK
VENT
PT
500
TO LEVEL
SENSORS
FILTER
AIR
COMPRESSOR
WATER
PRESSURE
SENSOR
HAND
VALVE
RELIEF
VALVE
PRESSURE
INDICATOR
PRESSURE
REGULATOR
(PR501)
CHECK
VALVE
RELIEF
VALVE
PI
500
PT
501
PRESSURE
SENSOR
TO DRUM
REAR AIR
BAGS
ORIFICES
(BANK OF 8)
TO AIR
ACTUATORS
HAND
VALVE
VENT
PRESSURE
INDICATOR
PI
501
VENT
TO DRUM
FRONT
AIR BAGS
LEVELING
VALVE (TYPICAL
1 OF 4)
ORIFICE
SOLENOID
MANIFOLD
(TYPICAL 1
OF4)
HAND
VALVE
PRESSURE
REGULATOR
(PR500)
VENT
HAND
VALVE
HAND
VALVE
DRAIN
HAND
VALVE