TM 10--3510--221--24
0007 00--1
CONTROL SYSTEM THEORY
OF OPERATION
0007 00
CONTROL SYSTEM
The control system provides the electrical interface between the external power and the LADS electrical and
electronic components. This system also controls all aspects of LADS automated operation and provides the
interface to the controls and indicators that the operator uses when performing laundry operations. Control system
operation consists of the following sub--operations.
INPUT POWER DISTRIBUTION AND CONDITIONING
External 208 VAC, 3--Phase, 50/60 HZ electrical power is connected to the disconnect switch (SW1) located in the
main control enclosure. This switch removes power from the LADS when turned off and provides power to the power
distribution block (TB1) when turned on. At the distribution block power is divided and distributed to circuit breakers
that protect 3--phase and single--phase circuits routed throughout the LADS. 3--phase power is connected to the
inverters and individual contactors used to supply power to the various motors. Single--phase 110 VAC power is
connected to a ground fault interrupt (GFI) circuit for external lighting and the control power switch (SW2). When SW2
is turned on power is applied to two DC power supplies. Power supplies (PS1 and PS2) are used to supply +5, +12,
and --12 volts direct current (VDC) power to various circuit boards used to control LADS operation. A phase monitor
(PM800) is connected to the power distribution block to continually analyze the input power provided to the LADs. If
an out of tolerance condition exists control power will be automatically removed.
EXTERNAL
POWER
(208 VAC,
3--PHASE,
50--60 HZ)
MAIN
DISCONNECT
SWITCH (SW1)
POWER
DISTRIBUTION
BLOCK (TB1)
INVERTER
HEATER
BLOWER
CONTACTORS/
PROTECTORS
208 VAC,
3--PHASE
CIRCUIT
BREAKERS
CONTACTORS/
PROTECTORS
DRYER
BLOWERS
WATER
PUMPS
INVERTERS
DRUM
MOTORS
CONTACTORS/
PROTECTORS
INVERTER
CONDENSER
FAN
THERMAL
FLUID PUMP
COOLING
FANS
110 VAC
FUSES
TERMINAL
BLOCK (TB2)
TERMINAL
BLOCK (TB6)
AIR SYSTEM
AUXILIARY
LIGHTING
GFI OUTLET
PHASE
MONITOR
FUSES
TERMINAL
BLOCK (TB9)
POWER
SUPPLY
(PS1)
CONTROL
POWER
SWITCH
(SW2)
110 VAC,
SINGLE PHASE
CIRCUIT
BREAKERS
FUSE
+12 VDC TO
CIRCUIT
BOARDS,
SENSORS,
SWITCHES.
AND VALVES
FUSES
+5, +12, --12
VDC TO
CIRCUIT
BOARDS
AND CARD
CAGE
110 VAC TO
CONTACTORS,
VALVES,
SWITCHES,
AND TB7
POWER
SUPPLY
(PS2)
TERMINAL
BLOCK (TB2)