TM 10--3510--221--24
0212 00--3/4 blank
DIGITAL I/O PCB REPLACEMENT -- Continued
0212 00
INSTALLATION
1. ESD. Connect ribbon cable (12) to connector J4 (13) on new digital I/O PCB (4).
2. ESD. Connect ribbon cable (10) to connector J3 (11).
3. ESD. Connect ribbon cable (8) to connector J2 (9).
4. ESD. Connect ribbon cable (6) to connector J1 (7).
5. ESD. Slide digital I/O PCB (4) into card cage (5). Make sure PCB is fully seated.
6. ESD. Slide retaining plate (2) forward and tighten two screws (1).
7. Turn handle (14) CW, then close door (15).
8. Secure door (15) to main control enclosure (16) by tightening eleven latches (17).
9. Perform a SYSTEM START--UP and test LAUNDRY CYCLE (TM 10--3510--221--10). Verify normal operation.
END OF WORK PACKAGE