TM 10-3510-222-10
2-11. PREPARATION FOR MOVEMENT - continued.
e.
Generator.
WARNING
Hot exhaust hoses must cool before disconnecting. Failure to let cool will cause burns.
(1)
Disconnect exhaust hoses.
(2)
Disconnect main power cable from generator and coil and store between water pump and generator.
(3)
Refer to TM 5-6115-585-12 for any questions about generator.
f.
Dryer.
(1)
Disconnect fuel lines from drum fill adapters and drain. Store fuel lines under dryer.
(2)
Remove drum fill adapter from 55-gallon (208 liter) drum or 5-gallon (19 liter) military gas can.
(3)
Remove drum extension from piping coupling if 55-gallon (208 liter) drum was used.
(4)
Install drum extension on return outlet drum fill adapter.
(5)
Disconnect air duct hose (dryer lint exhaust) from dryer. Compress and fasten hook. Store inside tumbler
barrel of dryer.
WARNING
Hot exhaust hoses must cool before disconnecting. Failure to let cool will cause burns .
(6)
Disconnect exhaust metal hoses. Store exhaust metal hose on center of Laundry Unit with three straps
that are attached to trailer bed..
g.
Dryer Bin.
(1)
Position dryer bin on Laundry Unit between generator and water heater.
(2)
Install four hexagon head cap screws and four lockwashers in dryer bin and Laundry Unit. (Hardware in
toolbox)
h.
Ground Rod.
(1)
Remove bare copper wire from electrical clamp on rod and store under generator.
(2)
Remove ground rod from ground and disassemble.
2-82