TM 10-3510-22210
2-7. ASSEMBLY AND PREPARATION FOR USE - continued.
f.
Nonmetallic Hose Drains - continued.
(3)
Remove quick disconnect cap from quick disconnect coupling half on washer/extractor drain piping.
CAUTION
Nonmetallic hoses can collapse. Make sure there are no collapsed nonmetallic hoses.
(4)
Connect one 25-foot (7.6 m), 2-1/2-inch-diameter nonmetallic hose (1) to washer quick coupling half (2)
and route the nonmetallic hose to a drain field.
g.
Main Power Cable. See figure 2-15. If not installed, install per substeps below. If installed, go to next step.
WARNING
Make sure generator is off prior to installing main power cable. Failure to observe may result in
death or serious injury.
(1)
Turn MASIER SWITCH to OFF, refer to TM 5-6115-585-12.
(2)
Remove dust cap from main power cable (1).
(3)
Remove dust cap from power distribution panel (2).
(4)
Connect main power cable (1) electrical plug connector to power distribution panel (2) left side receptacle
connector.
(5)
Connect pigtail end of main power cable to generator, refer to TM 5-6115-585-12.
Generator
Main Power Cable
L1
BLACK
L2
RED
L3
BLUE
LO
WHI
GROUND
GREEN
Change 1 2-46