TM 10-3510-222-24
2-76. CONNECTOR-SWITCH - continued.
NOTE
Wire numbers are stamped on each electrical wire. This
information, in conjunction with data on FO-5 Centrifugal Pump
Unit Wiring Diagram, may be used to connect wires if tags are lost
or illegible.
(d)
Connect wiring to new switch (5) as tagged.
(e)
Install two screws (15).
(f)
Install cover (14) and four screws (13).
c.
INSTALLATION
(1)
Position switch box (4) on water pump frame (16) and install two screws (11) and nuts (10).
(2)
Install connector (8), washer (9) and nut (7) on switch box (4).
NOTE
Wire numbers are stamped on each electrical wire. This
information, in conjunction with data on FO-5 Centrifugal Pump
Unit Wiring Diagram, may be used to connect wires if tags are lost
or illegible.
(3)
Connect wiring to switch (5) and receptacle (6) as tagged.
(4)
Install gasket (3) and cover (2) on switch box (4) with six screws (1).
2-173