TM 10-3510-222-24
2-75. SEDIMENT STRAINER AND OUTLET PIPING - continued.
d.
REPAIR
Repair consists of replacing damaged or missing components of the sediment strainer (7) and/or outlet piping (14).
e.
ASSEMBLY
NOTE
Install antiseize tape (teflon tape) on all male threads. Always wrap tape in the direction of the
threads.
(1)
Sediment Strainer (7).
(a)
Install coupling half (5) in body (4).
(b)
Install pipe nipple (15) in body (4).
(2)
Outlet Piping (14).
(a)
Install nipple (13) on tee (12).
(b)
Install coupling half (11) on tee (12).
(c)
Install coupling half (9) and gasket (10).
(d)
Install cap (8).
f.
INSTALLATION
NOTE
Install antiseize tape (teflon tape) on all male threads. Always wrap tape in the direction of the
threads.
(1)
Sediment Strainer (7). Install sediment strainer (7) on centrifugal pump unit (6).
(2)
Outlet Piping (14). Install outlet piping (14) on centrifugal pump unit (6).
2-171