TM 10-3510-222-24
3-37. ENCLOSURE BOX.
This task covers:
a. Removal
b. Repair
c. Installation
INITIAL SETUP
Tools
General Mechanics Tool Kit (App B, Item 1)
Electrical Repair Shop Equipment
(App B, Item 4)
Materials/Parts
Tags (App D, Item 4)
Equipment Condition
Laundry Unit shut down (TM 10-3510-222-10)
Circuit Breaker bracket removed (Para 3-38)
General Safety Instructions
WARNING
High voltage is present on this
equipment.
Do
not
perform
maintenance with power on. Death or
serious injury may result
a. REMOVAL
(1) Open enclosure box (1).
(2) Remove two screws (2), lockwashers (3), flat washers (4) and shield (5).
(3) Tag and disconnect all electrical wiring from voltage starter (6).
(4) Pull electrical wiring into power panel (8).
(5) Remove chase nipple (7) from power panel (8).
(6) Remove four screws (15), lockwashers (16) and panel (20).
(7) Remove three screws (10), lockwashers (11) and nuts (12).
(8) Remove enclosure box (1).
b. REPAIR
(1) Voltage Starter (6).
(a) Remove two screws (2), lockwashers (3), flat washers (4) and shield (5).
(b) Tag and disconnect electrical wiring from voltage starter (6).
(c) Remove three screws (13), starwashers (14) and voltage starter (6).
(d) Remove jumper wire from L1 and A2, refer to FO-6 Air Compressor Wiring Diagram.
(e) Remove three heaters (18) and six screws (17) from voltage starter 16).
NOTE
Hold reset button down while installing heaters.
(f)
Install three heaters (18) on new voltage starter (6). Secure with six screws (17).
3-86