TM 10-3510-222-24
3-37. ENCLOSURE BOX - continued
(g) Install jumper wire on L1 and A2. Refer to FO-6, Air Compressor Wiring Diagram.
(h) Position voltage starter (6) in enclosure box (1) and install three star washers (14) and screws (13).
NOTE
Wire numbers are stamped on each electrical wire. This information, in conjunction with data on
FO-6 Air Compressor Wiring Diagram, may be used to connect wires if tags are lost or illegible
(i)
Connect electrical wiring as tagged.
(j)
Position shield (5) in enclosure box (1) and install two flat washers (4), lockwashers (3) and screws (2).
(2) Heater (12).
NOTE
This procedure is for one heater, all other heaters are identical.
(a) Remove two screws (2), lockwashers (3), flat washers (4) and shield (5).
(b) Remove two screws (17) and remove heater (18).
(c) Press reset button (19) and position heater (18) on voltage starter (6) and install two screws (17).
(d) Position shield (5) in enclosure box (1) and install two flat washers (4), lockwashers (3) and screws (2).
(3) Enclosure Box (1).
(a) Remove case nipple (21) and coupling (9).
(b) Position coupling (9) on new enclosure box (1) and install case nipple (21).
c. INSTALLATION
(1) Position enclosure box (1) on power panel (8) and install chase nipple (7).
(2) Install three screws (10), lockwashers (11) and nuts (12).
(3) Install panel (20), four lockwashers (16) and screws (15).
(4) Pull electrical wiring into enclosure box (1).
NOTE
Wire numbers are stamped on each electrical wire This information, in conjunction with data on
FO-6 Air Compressor Wiring Diagram, may be used to connect wires if tags are lost or illegible
(5) Connect electrical wiring to voltage starter (6) as tagged.
(6) Install shield (5) with two screws (2), lockwashers (3) and flat washers (4).
(7) Press reset button (19) and close enclosure box (1).
(8) Install circuit breaker bracket (Para 3-38).
3-88