TM 10-3510-222-24
3-38. POWER PANEL - continued
b. REPAIR
(1) Circuit breakers, one 60 amp (25), five 20 amp (27).
(a) Open power panel door (21).
(b) Remove four screws (1), top and bottom brackets (2) and right and left brackets (3).
(c) Remove four screws (4) and circuit breaker bracket (5).
(d) Tag and disconnect electrical wiring to circuit breaker (25 and/or 27).
(e) Remove three screws each (26).
(f)
Remove circuit breaker (25 and/or 27).
(g) Install new circuit breaker (25 and/or 27).
NOTE
Wire numbers are stamped on each electrical wire. This information, in conjunction with data on
FO-1 Laundry Unit Interconnect Wiring Diagram, may be used to connect wires if tags are lost or
illegible
(h) Connect electrical wiring to circuit breaker (25 and/or 27).
(i)
Position circuit breaker bracket (5) on power panel (31) and install four screws (4).
(j)
Position right and left brackets (3), top and bottom brackets (2) and install four screws (1).
(k) Close power panel door (21).
(2) Connector (30).
(a) Open power panel door (21).
(b) Remove four screws (1), top and bottom brackets (2) and right and left brackets (3).
(c) Remove four screws (4) and circuit breaker bracket (5).
(d) Tag and disconnect electrical wiring to connector (30).
(e) Remove four screws (28), connector (30) and cap (29).
(f)
Remove electrical wiring from connector (30).
(g) Remove four screws (32), gasket (22), cover (23) and grommet (24).
(h) Install electrical wiring on new connector (30).
(i)
Install grommet (24), gasket (22), cover (23) and four screws (32).
(j)
Position connector (30) on power panel (31) and install four screws (28) and cap (29).
3-91