TM 10-3510-222-24
3-53. TIMER.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
General Mechanics Tool Kit (App B, Item 1)
Materials/Parts
Tags (App D, Item 4)
Equipment Condition
Laundry Unit shut down (TM 10-3510-222-10)
Cover removed (Para 3-42)
General Safety Instructions
WARNING
Voltage in this equipment is high enough to cause
serious injury or death. Do not perform this task
with power on.
a.
REMOVAL
(1)
Tag and disconnect wires from timer case (7).
(2)
Loosen screw (1) and pull up on handle (2).
(3)
Pull timer (3) out of control panel (8).
(4)
Remove four nuts (5), lockwashers (6) and screws (4).
(5)
Remove timer case (7) from control panel (8).
b.
INSTALLATION
(1)
Position timer case (7) in control panel (8) and secure with four screws (4), lockwashers (6) and
nuts (5).
(2)
Insert timer (3) in timer case (7) and pull down handle (2).
(3)
Tighten screw (1).
NOTE
Wire numbers are stamped on each electrical wire.
This information, in conjunction with data on FO-3,
Extractor Wiring Diagram, may be used to connect
wires if tags are lost or illegible.
(4) Connect wires to timer case (7) as tagged.
(5) Install cover (Para 3-42).
3-124