TM 10-3510-222-24
3-54. TERMINAL BOARD.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
General Mechanics Tool Kit (App B, Item 1)
Material/Parts
Tags (App D, Item 4)
Equipment Condition
Laundry Unit shut down (TM 10-3510-222-10)
Cover removed (Para 3-42)
General Safety Instructions
WARNING
Voltage in this equipment is high enough to cause
serious injury or death. Do not perform this task
with power on.
a.
REMOVAL
(1)
Tag and disconnect wires from terminal board (3).
(2)
Remove two screws (1), lockwashers (2) and terminal board (3).
b.
INSTALLATION
(1)
Position terminal board (3) in control panel (4) and secure with two screws (1) and lockwashers (2).
NOTE
Wire numbers are stamped on each electrical wire.
This information, in conjunction with data on FO-3,
Extractor Wiring Diagram, may be used to connect
wire, if tags are lost or illegible.
(2)
Connect wire as tagged.
(3)
Install cover (Para 3-42).
3-126