When a 3,000 Gallon freshwater tank was used:
Shut OFF the freshwater pump (1) at the roadside raceway (2) switch. Disconnect the 2 freshwater hose
(3) from the freshwater inlet panel (4) on the curbside of the container. While holding the end of the hose
above the water level in the freshwater tank (5), place the end of the hose (3) into the freshwater tank.
Install dust cap (6) on panel (4).
Open the gate valve (7) inside the freshwater inlet panel (4). Connect a garden hose to the threaded fitting
(8) at the end of the supply line and open the gate valve (9) to let the system drain. Open the freshwater
pump drain valve (10) to let the pump drain. Leave valves open after system has drained. Disconnect
garden hose from the threaded fitting (8). Drain the hose, coil it, and place inside CSSL.
WARNING
The 3,000 Gallon water tank is heavy. To avoid injuries, four persons are
required to prepare the CSSL for shipment.
Drain the 3,000 Gallon freshwater tank (5) in accordance with TM 5-5430-227-12&P. Remove the 2
freshwater hose (3) from the freshwater tank (5). Drain the hose, coil, and place inside CSSL. Place the
3,000 Gallon freshwater tank inside the CSSL.
WARNING
Avoid spillage of wastewater during shut down. Drain wastewater hoses
into an approved disposal facility. Keep wastewater hoses and 3,000
Gallon wastewater tank separate from freshwater equipment.
After the wastewater pump (11) has stopped running, shut off the pump (Circuit Breaker #16, Panel #1).
Drain the remaining water from the interior wastewater tank (12) by removing the drain plug (13) with an
adjustable wrench. Reinstall the plug after tank has drained.
When a municipal disposal system was connected:
Disconnect the 2 wastewater hose (14) from the wastewater panel (15) on the curbside of the container,
and drain it into the disposal connection. Disconnect 2 wastewater hose (14) from wastewater disposal
point. Coil the hose and place it inside the CSSL. Install dust cap (16) on panel (15).
When a 3,000 Gallon wastewater collection tank was connected:
Disconnect the 2 wastewater hose (14) from the wastewater panel (15) on the curbside of the container.
While holding the end of the hose above the water level in the 3,000 Gallon wastewater tank (17), place
the end of the hose into the wastewater tank. Install dust cap (16) on panel (15).