TM 10-3510-223-13&P 0026 00
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MODEL A
UNIT MAINTENANCE
0026 00-1/(2 Blank)
VENTILATION FAN
THIS SECTION COVERS:
Inspect
INITIAL SETUP
CSSL in operation
Maintenance Level
Unit
Tools and Special Tools
Materials/Parts
Tool Kit General Mechanic (WP 0045, Table 2, Item 1)
WARNING
This equipment operates at High Voltages. Use extreme caution.
Turn OFF power supply and disconnect ventilation fan power cable.
Touching a live wire can cause serious injury or death.
INSPECT
With the circuit breaker #22 on breaker panel #1 set to OFF, the ventilation fan switch (1) on the roadside
raceway (2) set to OFF, and the power cord (3) disconnected, inspect the ventilation fan from inside the
container for damage. Check the condition of the power cord (3) and twist lock connector for cuts, fraying,
and exposed wires. Check fan captive tiedown knobs (4) and tighten if necessary. Inspect fan from the
roof of the container for damage and clogging with debris. Remove debris as necessary. Refer an
inoperative or damaged ventilation fan to direct support maintenance.
2
1
3
4
END OF WORK PACKAGE