TM 10-3510-223-13&P
0043 00
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MODEL A
DIRECT SUPPORT MAINTENANCE
0043 00-1
SPACE HEATER
THIS SECTION COVERS:
Test, Repair, Replace
INITIAL SETUP
CSSL not in operation
Maintenance Level
Direct Support
Tools and Special Tools
Materials/Parts
Tool Kit, Electronic Equipment (WP 0045, Table 2, Item 3)
Wiping Rags (WP 0072, Table 1, Item 1)
WARNING
This equipment operates at High Voltages. Use extreme caution.
Observe all warnings, and follow all safety procedures. Touching a live
wire can cause serious injury or death.
TEST
Isolate electrical malfunction of the space heater as described in Procedure 2 of the Direct Support
Troubleshooting Procedures contained in work package 0029.
REPAIR
Before repairing the space heater (1), set circuit breaker #9 on power distribution panel #1(2) to OFF, and
disconnect the power cord (3) from the receptacle on the ceiling raceway (4). Repair the space heater by
removing it as described in the following procedures and replacing the power cord as described in work
package 0074, Figure 7.
REPLACE
Prior to replacing the space heater (1), open the rear doors (5) on the container to gain access.
Remove
To remove the space heater (1) from the mount (6), remove four screws (7) and washers (8) securing
space heater to the mount (6). Retain screws and washers.