TM 10-3510-223-13&P 0005 00
0005 00-37
When a 3,000 Gallon freshwater tank is used:
Shut OFF the freshwater pump (1) at the roadside raceway (2) switch (located on roadside raceway
beside power panels (19). Disconnect the 2 freshwater hose (3) from the freshwater inlet panel (4) on the
curbside of the container. While holding the end of the hose above the water level in the freshwater tank
(5), place the end of the hose (3) into the freshwater tank as shown. Install dust cap (6) on panel (4).
Open the gate valve (7) behind the freshwater inlet panel (4). Connect a garden hose to the threaded
fitting (8) at the end of the supply line and open the gate valve (9) to let the system drain. Open the
freshwater pump drain valve (10) to let the pump drain. Close valves after system has drained.
Drain the 3,000 Gallon freshwater tank (5) in accordance with TM 5-5430-227-12&P. Remove the 2
freshwater hose (3) from the freshwater tank. Drain the hose, coil, and set aside.
WARNING
Avoid spillage of wastewater. Drain wastewater hoses into an approved
disposal facility. Keep wastewater hoses away from freshwater hoses
and any freshwater supply in the vicinity. Serious health problems may
result from freshwater contamination.
After the wastewater pump (11) has stopped running, shut off the pump (Circuit Breaker #16, Panel #1).
Drain the remaining water from the interior wastewater tank (12) by removing the drain plug (13) with an
adjustable wrench. Reinstall the plug after tank has drained.
When a municipal disposal system is connected:
Disconnect the 2 wastewater hose (14) from the wastewater panel (15) on the curbside of the container,
and drain it into the disposal connection. Disconnect 2 wastewater hose (14) from wastewater disposal
point. Coil the hose and set it aside. Install dust cap (16) on panel (15).
When a 3,000 Gallon wastewater collection tank was connected:
Disconnect the 2 wastewater hose (14) from the wastewater panel (15) on the curbside of the container.
While holding the end of the hose above the water level in the 3,000 Gallon wastewater tank (17), place
the end of the hose into the wastewater tank as shown. Install dust cap (16) on panel (15).
Empty the 3,000 Gallon wastewater tank (17) in accordance with TM 5-5430-227-12&P. Remove the 2
wastewater hose (14) from the wastewater tank. Drain the hose, coil, and set aside.
Clean out dryer lint traps (18) and dispose of lint. Clean CSSL and TEMPER Section as described in work
package 0010 00.
Place 2 wastewater hose (14) and 3,000 Gallon wastewater tank (17) inside the TEMPER Section.
Remove garden hose from threaded fitting (8) on supply line. Drain the hose, coil, and place inside CSSL.
Coil and place 2 freshwater hose (3) together with 3,000 Gallon freshwater tank (5) inside CSSL.