TM 10-3510-223-13&P 0005 00
0005 00-41
When a 3,000 Gallon freshwater tank was used:
Shut OFF the freshwater pump (1) at the roadside raceway (2) switch. Disconnect the 2 freshwater hose
(3) from the freshwater inlet panel (4) on the curbside of the container. While holding the end of the hose
above the water level in the freshwater tank (5), place the end of the hose (3) into the freshwater tank as
shown. Install dust cap (6) on panel (4).
Open the gate valve (7) inside the freshwater inlet panel (4). Connect a garden hose to the hose fitting (8)
at the end of the supply line and open the gate valve (9) to let the system drain. Open the freshwater
pump drain valve (10) to let the pump drain. Close valves after system has drained.
WARNING
The 3,000 Gallon water tank is heavy. To avoid injuries, four persons are
required to prepare the CSSL for shipment.
Drain the 3,000 Gallon freshwater tank (5) in accordance with TM 5-5430-227-12&P. Remove the 2
freshwater hose (3) from the freshwater tank (5). Drain the hose, coil, and set aside. Disassemble and
place 3,000 Gallon freshwater tank (5) into bag in accordance with TM 5-5430-227-12&P.
After supply line has drained, disconnect garden hose from the hose fitting (8). Drain the hose, coil it, and
set aside.