TM 10-3510-224-13&P
0016 00
UNIT MAINTENANCE
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL)
NSN 3510-01-485-0457
INTERIOR SWITCHES AND RECEPTACLES
INSPECT, REPLACE
INITIAL SETUP:
Equipment Condition
Circuit breakers #10 in both left and right power
distribution panels set to OFF
Materials/Parts
Flashlight
Tools and Special Tools
Tool Kit, General Mech. Automotive (WP 0042, Table 2,
Item 1)
Personnel Required
One
INSPECT
1. Using a flashlight (in footlocker), inspect the light switch (1) located near the personnel entrance, and also the vent
fan switch (2) located on the right side power distribution panel.
2. Inspect the twist-lock receptacles (3) located in the overhead raceway (4) for damage.
ON
G
Y
W
X
4
3
4
1
2
0016 00-1