TM 10-3510-224-13&P
0016 00
WARNING
This equipment operates at high voltages. Use extreme caution. Turn circuit
breaker #8 in the right side power distribution panel to OFF and disconnect the
power supply before proceeding. Touching a live wire can cause serious injury or
death.
Vent Fan Switch.
1. To replace the vent fan switch (1) located on the right side power distribution panel (2), remove the power
distribution panel front cover assembly, refer to work package 0030 00 for the power distribution panel procedures.
2. Remove the threaded retainer (3) from the outside of the panel. Remove the four retaining screws and the switch
cover plate (5).
3. Remove the hex nut (6) securing the switch to the power distribution panel (2).
4. Pull the vent fan switch (1) back and away from the power distribution panel (2).
NOTE
Ensure that each wire is re-connected to the
appropriate terminal on the switch.
5. Remove the wires one at a time and re-connect each wire individually to the new switch.
6. After connections are complete, replace the switch and install the hex nut (6) on the outside of the panel.
7. Install the four retaining screws (4), the switch cover plate (5) and the threaded retainer (3).
8. Replace the power distribution panel front cover assembly as described in work package 0031 00.
0016 00-3