TM 10-3510-224-13&P
0023 00
UNIT MAINTENANCE
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL)
NSN 3510-01-485-0457
VENT FAN
INSPECT
INITIAL SETUP:
Equipment Condition
CSSL in operation, Circuit Breaker #8 (right side
power distribution panel) is turned OFF.
Materials/Parts
None Required
Tools and Special Tools
Tool Kit General Mech. Automotive (WP 0042, Table 2,
Item 1)
Personnel Required
One
WARNING
This equipment operates at high voltages. Use extreme caution. Turn OFF power
supply (circuit breaker #8 in right side power distribution panel). Touching a live
wire can cause serious injury or death.
INSPECT
1. Remove the dust screen (1) from the utility wall (2). Retain the securing hardware.
2. Inspect the dust screen and vent fan (3) from inside the container for damage.
3. Check the condition of the blades and that they are moving freely.
4. Remove debris caught in the fan housing as necessary. Replace the dust screen on the utility wall and secure,
using the retained hardware. Refer an inoperative or damaged vent fan to Direct Support Maintenance.
2
3
1
END OF WORK PACKAGE
0023 00-1/(2 Blank)