TM 10-3510-224-13&P
0024 00
UNIT MAINTENANCE
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL)
NSN 3510-01-485-0457
SPACE HEATER
INSPECT
INITIAL SETUP:
Equipment Condition
CSSL set up, circuit breakers #10 in both left and
right side Power Distribution Panels turned OFF.
Materials/Parts
None
Tools and Special Tools
Tool Kit General Mech. Automotive (WP 0042, Table 2,
Item 1)
Personnel Required
One
WARNING
This equipment operates at high voltages. Use extreme caution. Turn OFF power
supply (circuit breaker #15 in right and left side power distribution panels).
Touching a live wire can cause serious injury or death.
INSPECT
1. With circuit breaker #15 on right side power distribution panel set to OFF, inspect the space heater (1) for damage.
2. Check the condition of the power cord (2) for cuts, fraying, and exposed wires.
3. Check the heater installation hardware (3) and tighten if necessary. Inspect fan at rear of heater for damage and
/or debris.
4. If debris is found inside the grill, refer to direct support maintenance.
2
1
3
END OF WORK PACKAGE
0024 00-1/(2 Blank)