Table 1. Dryer Troubleshooting Procedures for Containerized Batch Laundry Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Drum doesn't turn
Ensure door (Figure 5, Item 1) is
securely latched and securely
mounted.
Refit panel and attempt restart.
Ensure lint compartment panel is fitted
Test and replace open lint
and safety switch (Figure 5, Item 2) is
compartment safety switch IAW
depressed and operating correctly.
Replace a broken drive belt IAW
Inspect drive belts (Figure 6, Item 3)
Replace open drive motor IAW
Test drive motor (Figure 6, Item 4)
Replace drive motor contactor
Check drive motor contactor (Figure
Replace controller IAW WP
Check for 24 VDC control voltage at
contactor (Figure 5, Item 5).
If condition persists, notify direct
support maintenance.
2
1
Figure 5. Drum doesn't Turn.