TM 10-3510-226-23
UNIT MAINTENANCE
CONTAINERIZED BATCH LAUNDRY
FLOW TRANSMITTER
REPLACE
INITIAL SETUP
Tools
Personnel Required
Tool Kit, General Mechanics: Automotive (WP 0086
Quartermaster and Chemical Equipment
Repairer 63J (1)
Materials/Parts
Equipment Condition
CBL Water Treatment system isolated.
REPLACE
Replace Flow Transmitters
NOTE
The CBL may be operated in minimum reuse or no reuse mode if necessary when
performing this maintenance task.
NOTE
The flow transmitter is monitored by the PLC. A failure of this component will be signaled
by an alarm and a message at the PLC.
1. Disconnect power by switching circuit breaker No. 8 to OFF.
2. Drain system.
3. Unscrew and disconnect the electrical quick disconnect (Figure 1, Item 1) from the flow transmitter
(Figure 1, Item 2).
NOTE
It may be necessary to loosen associated plumbing components to allow sufficient free
play to remove the transmitter.
4. Make note of the direction of flow, unscrew the unions (Figure 1, Item 3), and remove the transmitter
(Figure 1, Item 2).
5. Unscrew the union halves (Figure 1, Item 3) from the transmitter (Figure 1, Item 2).
6. Apply pipe sealer compound to the male threads of the transmitter (Figure 1, Item 2), and screw the
union halves (Figure 1, Item 3) onto the transmitter (Figure 1, Item 2).
7. Install the transmitter (Figure 1, Item 2) into the mount, and connect unions (Figure 1, Item 3).
Ensure unions are tight, but do not overtighten.
8. Connect electrical quick disconnect (Figure 1, Item 1).
9. Connect power, and monitor for normal operation.