TM 10-3510-226-23
UNIT MAINTENANCE
CONTAINERIZED BATCH LAUNDRY
LEVEL SENSOR
TEST, REPLACE
INITIAL SETUP
Tools
Personnel Required
Tool Kit, General Mechanics: Automotive (WP
Quartermaster and Chemical Equipment Repairer
63J (1)
Materials/Parts
Equipment Condition
CBL shutdown
References
TM 10-3510-226-10
TEST
Test the Level Sensors
1. Enter the system status menu on the PLC, and then go to digital status.
2. Locate the WTS and Nano level readings (Figure 1, Item 1) - there should be an ON or OFF value
after "IO".
3. Run the Water Treatment System (WTS) through an initial fill (#1) or top off cycle (#30), and monitor
the values for the WTS Level and Nano Level. No value change after the tank fills, or an overflow
condition, indicates a failure of the level sensor. Refer to TM 10-3510-226-10 for information on
performing an initial fill or top off.
1
Figure 1. Test the Level Sensors.