TM 10-3510-226-23
0033 00
REPLACE-CONTINUED
NOTE
It may be necessary to strip the drainage tank of fittings to install on the replacement tank.
14. Install replacement tank (Figure 2, Item 1) and secure in place with bolts.
15. Install pump (Figure 2, Item 12) and retain in place with fasteners.
16. Connect discharge hose to pump (Figure 2, Item 12) and secure with hose clamp.
17. Install watertight tank penetration (Figure 2, Item 11) into replacement tank (Figure 2, Item 1), if
necessary.
18. Route pump cord through watertight tank penetration (Figure 2, Item 11) and tighten.
19. Reinstall pump cord plug (Figure 2, Item 10) onto pump cord.
20. Connect hoses (Figure 2, Item 9) to tank (Figure 2, Item 1) and secure with clamps.
21. Install top (Figure 2, Item 8) of drainage tank.
22. Install manual lift knob (Figure 2, Item 2) onto waste tank pump P-5 (waste tank only).
23. Connect pump cord plug (Figure 2, Item 10) to pump receptacle, and monitor for normal operation.
0033 00-5