TM 10-3510-226-23
0032 00
UNIT MAINTENANCE
CONTAINERIZED BATCH LAUNDRY
WATER PANELS
SERVICE
INITIAL SETUP
Tools
Personnel Required
Shop Equipment, Automotive Maintenance and
Quartermaster and Chemical Equipment Repairer 63J
Repair: Organizational Maintenance, Common
(1)
Equipment Condition
Materials/Parts
None Required
CBL shut down and drained
SERVICE
Clean the Water Panel Fittings
1. Disconnect hoses from the water panels (Figure 1, Item 1).
2. Clean corrosion from fitting (Figure 1, Item 2).
3. Reconnect hoses.
1
2
Figure 1. Clean the Water Inlet Panel Fitting.
END OF WORK PACKAGE